Gaseous hydrogen land vehicle refuelling connection devices — Part 1: Flow capacities up to and including 120 g/s
Primary tabs
This document specifies the design, safety and operation characteristics of gaseous hydrogen land vehicle (GHLV) refuelling connectors.
GHLV refuelling connectors consist of the following components, as applicable:
—
receptacle and protective cap (mounted on vehicle);
—
nozzle;
—
communication hardware.
This document is applicable to refuelling connectors which have nominal working pressures or hydrogen service levels up to 70 MPa and maximum flow rates up to 120 g/s.
This document is not applicable to refuelling connectors dispensing blends of hydrogen with natural gas.